Introducing the Teledyne CETAC Aridus3 Desolvating Nebulizer System

Posted by Betsey Seibel on Aug 28, 2017 10:35:45 AM

 

Aridus3.pngTeledyne CETAC is one of the industry leaders in nebulizer systems, offering a comprehensive line of specialized sample introduction accessories for ICP-AES and ICP-MS. Among our systems are the Marin-5 Enhanced Nebulizer System, the U5000AT+ Ultrasonic Nebulizer, the U6000AT+ Ultrasonic Nebulizer & Membrane Desolvator and the Aridus II Desolving Nebulizer. The newest member of the CETAC sample introduction family is the Aridus3 Desolvating Nebulizer System, which is a 4th generation of a specialized liquid sample introduction accessory for ICP-MS.

The Aridus3 offers analyte element sensitivity that is enhanced 10 times or greater and significant reduction of solvent-based interferences such as oxides and hydrides. Aridus is widely used in a variety of ICP-MS applications, including geochemistry, geology, clinical, pharmaceutical and semiconductor. The Aridus3 can be used in a variety of ICP-MS applications, including geology, semi-conductors, pharmaceuticals, and clinical samples.

 

In a news release, Teledyne CETAC Nebulizer Product Manager Fred Smith said, The Aridus3 offers a number of important new benefits based on feedback from AridusII customers around the world.”

 

Among the key benefits of the Aridus3 system are the following:

  • Enhanced analyte sensitivity (10 times or more), depending on liquid sample uptake rate
  • Low-volume sample uptake rates of 50, 100, or 200 microliters/min, preserving valuable sample
  • C-Flow PFA nebulizer with integrated autosampler probe for use with Teledyne CETAC ASX-112FR MicroAutosampler
  • Heated PFA spray chamber for higher sample transport efficiency
  • Both PFA nebulizer and PFA spray chamber are behind a secured door to alleviate electrostatic effects
  • Inert fluoropolymer membrane for resistance to acids (including HF) and low oxide and hydride levels
  • Built-in mass flow controllers (MFCs) for precise setting of Ar sweep gas and N2 addition gas
  • Convenient computer software control of spray chamber temperature, membrane oven temperature and both Ar sweep gas and N2 addition gas allows remote tuning if the Aridus3 is placed in a clean enclosure
  • New Flow Saver software application allows the user to preset shut off of Ar and N2 gas flows after completion of an overnight run, saving valuable gases
  • New removable membrane heater block for ease of cleaning or replacement

Significant upgrades with the Aridus3 include new; dedicated mass-flow controllers with computer software control that set the Ar sweep gas and N2 addition gas glows, easing the tuning process.  A novel removable membrane oven assembly greatly simplifies cleaning and maintenance, while a software Flow Saver application allow preset shut-off of valuable gases after long unattended sample runs.

Smith added, “The development of new and improved accessories for the atomic spectroscopy marketplace is a constant process at Teledyne CETAC and this will continue with the Aridus product line.”

Download the Aridus3 Product Brochure, and visit TeledyneCETAC.com to learn more about CETAC’s line of nebulizers and accessories for ICP-AES and ICP-MS.